<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>RE-2554 &#8211; MultiTech Solution</title>
	<atom:link href="https://multitechsolution.co.in/product-tag/re-2554/feed/" rel="self" type="application/rss+xml" />
	<link>https://multitechsolution.co.in</link>
	<description>Your One-Stop Partner for Printing, Scanning, Copying &#38; Faxing in Mehsana</description>
	<lastBuildDate>Wed, 27 Aug 2025 07:33:44 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://multitechsolution.co.in/wp-content/uploads/2025/08/cropped-favicon-32x32.jpg</url>
	<title>RE-2554 &#8211; MultiTech Solution</title>
	<link>https://multitechsolution.co.in</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>RE-2554</title>
		<link>https://multitechsolution.co.in/product/re-2554/</link>
		
		<dc:creator><![CDATA[sanhbarot]]></dc:creator>
		<pubDate>Mon, 18 Aug 2025 09:05:01 +0000</pubDate>
				<guid isPermaLink="false">https://multitechsolution.co.in/newsite/?post_type=product&#038;p=1765</guid>

					<description><![CDATA[<ul>The microprocessor based UL listed 4 Zone conventional fire alarm control panel, the system has 16 X 2 LCDcharacter,4 zones detection circuit,, 3 common potential free contacts &#38;2 common NAC sounder output, inbuilt Rs-485 for repeater connectivity,wall/ceiling mounted, Switch mode power supply- SMPS &#38; Battery polarity &#38; Deep discharge protection.</ul>
<ul>RE-2554 fire alarm control panel is designed with unique protocol to be used for small &#38; medium establishments, Schools, hospitals, hotels, banks, commercial building, and small scale industries. The system is user friendly with includes all standard to ensure ease for use and high reliability.</ul>
&#160;]]></description>
										<content:encoded><![CDATA[<ul>
<li>Switched Mode Power Supply.</li>
<li>Modular Construction</li>
<li>Auto Resettable Fuse</li>
<li>Surge Protection for all Input and outputs.</li>
<li>Programmable AC loss delay/Trouble Remainder/Alarm Verification</li>
<li>Battery polarity reversible protection</li>
<li>Surface Mount Technology</li>
<li>Over All current consumption is low.</li>
<li>Fully complies with UL -864 and NFPA-72.</li>
<li>Rugged CRCA sheet with powder coated finish.</li>
<li>Operates on 110 – 220v 50 /60 Hz, AC Mains power supply.</li>
<li>16×2 Dot Matrix LCD Display.</li>
<li>4/8 Class B Style ‘B ‘ or Style ’C’ initiating device circuit (IDC).
<ul>
<li>All zones accept smoke detectors and any normally open contact device.</li>
<li>Any Zone can be configured as Alarm or supervisory Zone.</li>
</ul>
</li>
<li>2ClassBNotificationApplianceCircuits(NAC).</li>
<li>NAC shall be programmed as silenceable or Non Silenceable.</li>
<li>Supervisory Zone shall be Latching or Resettable.</li>
<li>Standby (battery) backup 24v DC power supply with built in charger</li>
<li>Error free Fire / Fault status in unambiguous colored LED indication.</li>
<li>System ON indication.</li>
<li>Main, Standby status audible and visual indication.</li>
<li>Battery Low visual warning with audible tone.</li>
<li>FormC relays for fire, fault and supervisory.</li>
<li>Resettable / Steady 24V D.C. Output.</li>
<li>RS 485 Communication facility (Optional).</li>
<li>Lamp Test facility.</li>
<li>All field wiring circuits are Power limited except 110 – 220v AC and Battery.</li>
<li>All field wiring circuits are supervised.</li>
<li>Walk Test facility.</li>
<li>Zone Isolation facility with loop voltage cut off.</li>
<li>Earth fault annunciation facility at 0 ohms.</li>
<li>AC Low voltage cutoff.</li>
<li>Programmable AC loss delay.</li>
<li>Programmable Alarm verification.</li>
<li>Programmable Trouble reminder.</li>
<li class="active">
<div class="auto-format ui--animation">
<h3>Electrical Specification</h3>
<table>
<tbody>
<tr>
<td><strong>Primary Power</strong><br />
120 – 220VAC ± 10%, 50 Hz, 2.5Amps.<strong>Standby Power</strong><br />
24V D.C (2 Nos of 12v, 12Ah Sealed Lead acid battery).<br />
Quiescent current: 120mA</td>
<td><strong>Initiating Device Circuits</strong><br />
All zones are Class B Style B/C operation (Programmable).<br />
Normal Operating Voltage: 14 – 21 VDC.<br />
Alarm Current: 15 – 30mA.<br />
Short Circuit Current: 45mA Maximum.<br />
Loop resistance: 100 ohms Maximum.<br />
End-Of-Line Resistor: 3K9, 1/2watt<br />
Standby Current: 7mA (2mA for Detectors)</td>
</tr>
<tr>
<td><strong>Operating Condition</strong><br />
Operating Temperature 0 – 49° C/32-120° F.<br />
Relative Humidity 93 ± 2% RH (non- condensing) at 32 ±2° C/90 ±3° F.</td>
<td></td>
</tr>
<tr>
<td><strong>Charging Circuit</strong><br />
Charging Voltage 28.2V, ±0.5V<br />
Charging Current 800mA (Max.).</td>
<td><strong>Notification Appliance Circuits</strong><br />
Class B Style – Y wiring<br />
Operating Nominal Voltage: 24VDC<br />
Special Application Current for all NACs: 1.2Amps (0.6A per circuit)<br />
Line Drop: 1.8V<br />
End-Of-Line Resistor: 3K9, 1/2watt</td>
</tr>
<tr>
<td><strong>D.C. Output</strong><br />
Supervised 24VDC regulated, 300mA Max.</td>
<td></td>
</tr>
<tr>
<td><strong>Common Relays</strong><br />
Type : Form C<br />
No of Relays : 3<br />
Relay Contact Rating : 2Amps @ 30 VDC,<br />
0.5Amps @ 125VAC.<br />
Power Factor : 1.0</td>
<td></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h3>Mechanical Specification</h3>
<table border="0">
<tbody>
<tr>
<td>Dimensions</td>
<td>:</td>
<td>(440W X 340H X 120D)</td>
</tr>
<tr>
<td>Color</td>
<td>:</td>
<td>Red / White</td>
</tr>
<tr>
<td>Construction</td>
<td>:</td>
<td>18 Gauge (1.22mm) CRCA sheet with powder-coated Finish</td>
</tr>
<tr>
<td>IP Rating</td>
<td>:</td>
<td>IP50</td>
</tr>
<tr>
<td>Cable Entry</td>
<td>:</td>
<td>11xø19mm Knockout in top of the cabinet<br />
10xø22.25mm Knockout in top of the cabinet</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h3>Ordering Information</h3>
<table border="1">
<tbody>
<tr>
<th>Model</th>
<th>Description</th>
</tr>
<tr>
<td>RE- 2554-W</td>
<td>4 Zones</td>
</tr>
<tr>
<td>RE- 2554-R</td>
<td>4 Zones</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><strong>Note:</strong><br />
W-White Color,<br />
R- Red Color</p>
<p>&nbsp;</p>
<h3>Compatible Devices</h3>
<table border="1">
<tbody>
<tr>
<th>Models</th>
<th>Description</th>
</tr>
<tr>
<td>RE-316S-2L</td>
<td>Photoelectric Smoke detector with base.</td>
</tr>
<tr>
<td>RE-316H-2L</td>
<td>Heat detector with base.</td>
</tr>
<tr>
<td>RE-316SH-2L</td>
<td>Photoelectric &amp; Heat detector with base</td>
</tr>
<tr>
<td>RE-314</td>
<td>Common base for above</td>
</tr>
<tr>
<td>RE-716MR</td>
<td>MCP Red</td>
</tr>
<tr>
<td>RE-716MG</td>
<td>MCP Green</td>
</tr>
<tr>
<td>RE-716MY</td>
<td>MCP Yellow</td>
</tr>
<tr>
<td>RE-24CS</td>
<td>Mini Horn</td>
</tr>
<tr>
<td>RE-24SS</td>
<td>Sounder cum Strobe</td>
</tr>
<tr>
<td>RE-Monitor</td>
<td>24VDC Output for Monitor Module</td>
</tr>
<tr>
<td>RE-3K9</td>
<td>End Of Line Resistor</td>
</tr>
</tbody>
</table>