<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Detectors &#8211; MultiTech Solution</title>
	<atom:link href="https://multitechsolution.co.in/product-category/fire-security-2/detectors/feed/" rel="self" type="application/rss+xml" />
	<link>https://multitechsolution.co.in</link>
	<description>Your One-Stop Partner for Printing, Scanning, Copying &#38; Faxing in Mehsana</description>
	<lastBuildDate>Wed, 27 Aug 2025 07:33:44 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://multitechsolution.co.in/wp-content/uploads/2025/08/cropped-favicon-32x32.jpg</url>
	<title>Detectors &#8211; MultiTech Solution</title>
	<link>https://multitechsolution.co.in</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Gas Leak Detector RE 386-LP</title>
		<link>https://multitechsolution.co.in/product/gas-leak-detector-re-386-lp/</link>
		
		<dc:creator><![CDATA[sanhbarot]]></dc:creator>
		<pubDate>Mon, 18 Aug 2025 09:18:01 +0000</pubDate>
				<guid isPermaLink="false">https://multitechsolution.co.in/newsite/?post_type=product&#038;p=1774</guid>

					<description><![CDATA[<ul>
 	<li>Advanced algorithms Provide advanced detection, discrimination.</li>
 	<li>Stable gas sensing chamber. No adjustment or replacement required</li>
 	<li>High immunity against unwanted alarms</li>
 	<li>Surface-mount device (SMD) circuit board design</li>
 	<li>4-wire system operation</li>
 	<li>Detector auto-reset once gas levels fall below alarm threshold levels</li>
 	<li>Internal reed switch for hush and test functions</li>
 	<li>DC 24 V operation</li>
 	<li>N/O alarm relay output</li>
 	<li>70 dB internal sounder</li>
 	<li>Easy installation. No programming required</li>
 	<li>Connects to zone monitor for use with addressable control and indicating equipment</li>
 	<li>Sleek low-profile housing design</li>
 	<li>Low maintenance</li>
</ul>]]></description>
										<content:encoded><![CDATA[<div class="auto-format ui--animation">
<h3>Specification</h3>
<table border="0">
<tbody>
<tr>
<td>Operating Voltage</td>
<td>:</td>
<td>(21 ~ 27)VDC</td>
</tr>
<tr>
<td>Start-up current</td>
<td>:</td>
<td>≤120mA</td>
</tr>
<tr>
<td>Start-up time</td>
<td>:</td>
<td>≤10min</td>
</tr>
<tr>
<td>Quiescent Current</td>
<td>:</td>
<td>45 mA</td>
</tr>
<tr>
<td>Alarm Current (max)</td>
<td>:</td>
<td>60 mA</td>
</tr>
<tr>
<td>Sampling Time</td>
<td>:</td>
<td>3 s ~ 5 s</td>
</tr>
<tr>
<td>Reset Voltage</td>
<td>:</td>
<td>≤1 V</td>
</tr>
<tr>
<td>Reset Time</td>
<td>:</td>
<td>≤5 s</td>
</tr>
<tr>
<td>Alarm response threshold</td>
<td>:</td>
<td>≤ 0.25 LELC3H8</td>
</tr>
<tr>
<td>Alarm relay</td>
<td>:</td>
<td>SPST. N/O 1.0 A @ DC 30 V / 0.5 A @ AC 125 V</td>
</tr>
<tr>
<td>Auto reset time</td>
<td>:</td>
<td>&lt; 30s</td>
</tr>
<tr>
<td>Sounder output</td>
<td>:</td>
<td>≥ 70 dB @ 3m</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>:</td>
<td>-10° C ~ 50° C</td>
</tr>
<tr>
<td>Operating humidity</td>
<td>:</td>
<td>0 % ~ 95 % RH, non-condensing</td>
</tr>
<tr>
<td>Storage temperature</td>
<td>:</td>
<td>-25° C ~ 80° C</td>
</tr>
<tr>
<td>Operating humidity</td>
<td>:</td>
<td>0 % ~ 98 % RH, non-condensing</td>
</tr>
<tr>
<td>Quiescent condition indicator</td>
<td>:</td>
<td>Single continuous emitting green LED</td>
</tr>
<tr>
<td>Alarm condition indicator</td>
<td>:</td>
<td>Flashing red LED</td>
</tr>
<tr>
<td>Dimensions (excluding contacts)</td>
<td>:</td>
<td>ϕ 100mm X 38 mm</td>
</tr>
<tr>
<td>Ingress protection rating</td>
<td>:</td>
<td>IP-32</td>
</tr>
</tbody>
</table>
<h3>Compatible Devices</h3>
<table border="1">
<tbody>
<tr>
<th>Models</th>
<th>Description</th>
</tr>
<tr>
<td>RE-314B</td>
<td>4-wire Detector Base</td>
</tr>
<tr>
<td>RE-717MZ</td>
<td>Analogue Addressable Zone Module</td>
</tr>
</tbody>
</table>
<h3>Ordering Information</h3>
<table border="1">
<tbody>
<tr>
<th>Model</th>
<th>Description</th>
<th>Gas</th>
</tr>
<tr>
<td>RE-386LP</td>
<td>Conventional Propane Gas (LPG) Detector<br />
with Relay Output</td>
<td>C3H8</td>
</tr>
</tbody>
</table>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RE-428DU-C</title>
		<link>https://multitechsolution.co.in/product/re-428du-c/</link>
		
		<dc:creator><![CDATA[sanhbarot]]></dc:creator>
		<pubDate>Mon, 18 Aug 2025 09:14:48 +0000</pubDate>
				<guid isPermaLink="false">https://multitechsolution.co.in/newsite/?post_type=product&#038;p=1772</guid>

					<description><![CDATA[<ul>
 	<li>High efficient single sampling tube</li>
 	<li>Easy to install</li>
 	<li>One-pipe air sampling system</li>
 	<li>Patented venturi pipe and duct housing</li>
 	<li>Test hole on cover</li>
 	<li>Simple service and maintenance</li>
</ul>]]></description>
										<content:encoded><![CDATA[<div class="auto-format ui--animation">
<h3>Electrical Specification</h3>
<table border="0">
<tbody>
<tr>
<td>Operating Voltage</td>
<td>:</td>
<td>9 ~ 33V DC</td>
</tr>
<tr>
<td>Operating Temperature</td>
<td>:</td>
<td>-10°C to 50°C</td>
</tr>
<tr>
<td>Humidity</td>
<td>:</td>
<td>0 – 95% RH, non-condensing</td>
</tr>
<tr>
<td>Reset Voltage</td>
<td>:</td>
<td>less than 1V</td>
</tr>
<tr>
<td>Start-Up Current</td>
<td>:</td>
<td>120 μA</td>
</tr>
<tr>
<td>Alarm Current</td>
<td>:</td>
<td>40 mA.(Max)</td>
</tr>
<tr>
<td>Remote Output</td>
<td>:</td>
<td>15mA maximum open collector</td>
</tr>
<tr>
<td>Smoke Sensitivity</td>
<td>:</td>
<td>(1.96 ± 0.76) % / ft</td>
</tr>
<tr>
<td>Air Velocity</td>
<td>:</td>
<td>0 – 4000 fpm</td>
</tr>
<tr>
<td>Dimensions</td>
<td>:</td>
<td>(241 L X 195 W X 68 D) mm</td>
</tr>
<tr>
<td>Weight</td>
<td>:</td>
<td>1.04 kg</td>
</tr>
<tr>
<td>Air Sampling Tube</td>
<td>:</td>
<td>Aluminium. ( Hole Diameter 1.5” (38 mm)</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h3>Ordering Information</h3>
<table border="1">
<tbody>
<tr>
<th>Model</th>
<th>Description</th>
</tr>
<tr>
<td>RE-428DU-C</td>
<td>Conventional Duct Smoke Detector</td>
</tr>
<tr>
<td>RE-428DU-S2</td>
<td>Sampling tube length: 2 ft (0.6 m)</td>
</tr>
</tbody>
</table>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RE 316S-2L</title>
		<link>https://multitechsolution.co.in/product/re-316s-2l/</link>
		
		<dc:creator><![CDATA[sanhbarot]]></dc:creator>
		<pubDate>Mon, 18 Aug 2025 09:12:13 +0000</pubDate>
				<guid isPermaLink="false">https://multitechsolution.co.in/newsite/?post_type=product&#038;p=1771</guid>

					<description><![CDATA[<ul>
 	<li>UL listed.</li>
 	<li>Dual LED’s for 360° visibility.</li>
 	<li>Advanced detection and communication protocol.</li>
 	<li>Easy installation and maintenance.</li>
 	<li>Sleek low-profile housing design.</li>
 	<li>Regular 100mm base.</li>
</ul>]]></description>
										<content:encoded><![CDATA[<div class="auto-format ui--animation">
<h3>Electrical Specification</h3>
<table border="0">
<tbody>
<tr>
<td>Operating Voltage</td>
<td>:</td>
<td>9 ~ 33V DC</td>
</tr>
<tr>
<td>Operating Temperature</td>
<td>:</td>
<td>-10 °C to 37.8 °C</td>
</tr>
<tr>
<td>Storage Temperature</td>
<td>:</td>
<td>-10 °C to 60 °C</td>
</tr>
<tr>
<td>Humidity</td>
<td>:</td>
<td>0 – 95% RH, non-condensing</td>
</tr>
<tr>
<td>Reset Voltage</td>
<td>:</td>
<td>less than 1V</td>
</tr>
<tr>
<td>Standby Current</td>
<td>:</td>
<td>-50 μA.</td>
</tr>
<tr>
<td>Start up Time</td>
<td>:</td>
<td>60s.</td>
</tr>
<tr>
<td>Start-Up Current</td>
<td>:</td>
<td>170 μA.</td>
</tr>
<tr>
<td>Alarm Current</td>
<td>:</td>
<td>90 mA.(Max).</td>
</tr>
<tr>
<td>Remote Output</td>
<td>:</td>
<td>15mA maximum open collector</td>
</tr>
<tr>
<td>Smoke Sensitivity</td>
<td>:</td>
<td>(1.96 ± 0.76) % / ft</td>
</tr>
<tr>
<td>Air Velocity</td>
<td>:</td>
<td>0 – 4000 fpm.</td>
</tr>
<tr>
<td>Cycle time</td>
<td>:</td>
<td>5 Sec</td>
</tr>
<tr>
<td>Installation Space</td>
<td>:</td>
<td>5 meters</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h3>Mechanical Specification</h3>
<table border="0">
<tbody>
<tr>
<td>Height</td>
<td>:</td>
<td>46 mm with base</td>
</tr>
<tr>
<td>Diameter</td>
<td>:</td>
<td>100 mm dia</td>
</tr>
<tr>
<td>Weight</td>
<td>:</td>
<td>130g with base</td>
</tr>
<tr>
<td>IP Rating</td>
<td>:</td>
<td>IP – 42</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h3>Compatible Devices</h3>
<table border="1">
<tbody>
<tr>
<th>Models</th>
<th>Description</th>
</tr>
<tr>
<td>RE-314B</td>
<td>Normal Base</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h3>Ordering Information</h3>
<table border="1">
<tbody>
<tr>
<th>Model</th>
<th>Description</th>
</tr>
<tr>
<td>RE 316S – 2L</td>
<td>Conventional Photoelectric smoke detector with base</td>
</tr>
</tbody>
</table>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RE 316SH-2L</title>
		<link>https://multitechsolution.co.in/product/re-316sh-2l/</link>
		
		<dc:creator><![CDATA[sanhbarot]]></dc:creator>
		<pubDate>Mon, 18 Aug 2025 09:10:29 +0000</pubDate>
				<guid isPermaLink="false">https://multitechsolution.co.in/newsite/?post_type=product&#038;p=1769</guid>

					<description><![CDATA[<ul>
 	<li>UL Approved.</li>
 	<li>Dual LED’s for 360° visibility.</li>
 	<li>Advanced detection and communication protocol.</li>
 	<li>Easy installation and maintenance.</li>
 	<li>Sleek low-profile housing design.</li>
 	<li>Regular 100mm base.</li>
</ul>]]></description>
										<content:encoded><![CDATA[<div class="auto-format ui--animation">
<h3>Electrical Specification</h3>
<table border="0">
<tbody>
<tr>
<td>Operating Voltage</td>
<td>:</td>
<td>9 ~ 33V DC</td>
</tr>
<tr>
<td>Reset Voltage</td>
<td>:</td>
<td>less than 1V</td>
</tr>
<tr>
<td>Start-Up Current</td>
<td>:</td>
<td>120 μA.</td>
</tr>
<tr>
<td>Alarm Current</td>
<td>:</td>
<td>40 mA (Max)</td>
</tr>
<tr>
<td>Remote Output</td>
<td>:</td>
<td>15 mA maximum open collector</td>
</tr>
<tr>
<td>Thermal Rating</td>
<td>:</td>
<td>59 °C (138 °F)</td>
</tr>
<tr>
<td>Rate of Raise of Temp</td>
<td>:</td>
<td>11.1°C / min (20°F/min)</td>
</tr>
<tr>
<td>Smoke Sensitivity</td>
<td>:</td>
<td>(1.9 ± 0.76) % / ft</td>
</tr>
<tr>
<td>Air Velocity</td>
<td>:</td>
<td>0 – 4000 fpm.</td>
</tr>
<tr>
<td>Operating Temperature</td>
<td>:</td>
<td>-10 °C to 37.8 °C</td>
</tr>
<tr>
<td>Humidity</td>
<td>:</td>
<td>0 – 95% RH, non-condensing</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h3>Mechanical Specification</h3>
<table border="0">
<tbody>
<tr>
<td>Height</td>
<td>:</td>
<td>46 mm with base</td>
</tr>
<tr>
<td>Diameter</td>
<td>:</td>
<td>100 mm dia</td>
</tr>
<tr>
<td>Weight</td>
<td>:</td>
<td>130 g with base</td>
</tr>
<tr>
<td>IP Rating</td>
<td>:</td>
<td>IP – 42</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h3>Compatible Devices</h3>
<table border="1">
<tbody>
<tr>
<th>Models</th>
<th>Description</th>
</tr>
<tr>
<td>RE-314B</td>
<td>Normal Base</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h3>Ordering Information</h3>
<table border="1">
<tbody>
<tr>
<th>Model</th>
<th>Description</th>
</tr>
<tr>
<td>RE 316SH-2L</td>
<td>Photoelectric RE 316SH-2L &amp; Heat Detector</td>
</tr>
</tbody>
</table>
</div>